    These plugin systems are quite interesting, they allow renters for example to get some benefits of Solar without having to make permanent installs. The systems a lot cheaper than a full setup but obviously don’t produce the same amount of power. I first saw them appearing in France and then since Germany changed the law to allow them its good to see it flourishing there too. This isn’t going to save the planet but its a little step of improvement.

    400 Euro isn’t bad for all the fittings and inverter and the big benefit of these DIY systems is you just put them together and connect them to a standard wall socket. Constantly just saves you money on your bills when there is sunshine. Its also not enough power that its worth dealing with export tariffs but in countries where smart meters already exist it could be part of the mix.

    • catloaf@lemm.ee
      link
      fedilink
      English
      arrow-up
      10
      ·
      5 months ago

      You just plug them into an outlet? Is there no safety concern about backfeeding power, especially if someone turns off the breaker and expects a circuit to be de-energized?

      • zaphod@sopuli.xyz
        link
        fedilink
        English
        arrow-up
        20
        ·
        5 months ago

        They’re not supposed to be grid-forming and should turn off if there’s no grid voltage. And if you turn off a breaker you should always check that there’s no voltage, you might’ve turned off the wrong breaker.

        • catloaf@lemm.ee
          link
          fedilink
          English
          arrow-up
          3
          ·
          5 months ago

          That’s good then. Although I hope they also considered what happens if there’s two of them on a circuit, because if the mains power goes off, but there’s another panel on the same circuit, they’d each see the other’s voltage on the line, right?

          And yeah, you should verify that a circuit is de-energized after you flip the breaker, but I’ve seen both some real weird electrical work, and some electricians who aren’t that careful.

          • SkavarSharraddas@gehirneimer.de
            link
            fedilink
            arrow-up
            4
            ·
            5 months ago

            Although I hope they also considered what happens if there’s two of them on a circuit

            The regulations allow only for one. If you want a bigger install than that you need individual approval I think.

            • catloaf@lemm.ee
              link
              fedilink
              English
              arrow-up
              3
              ·
              5 months ago

              The panels themselves are DC, but there’s an inverter feeding 120V 60Hz (or whatever) into the wall, right?

              • silence7@slrpnk.netOP
                link
                fedilink
                English
                arrow-up
                6
                arrow-down
                1
                ·
                edit-2
                5 months ago

                Yes, but it’s a system that is designed to sync with the frequency of whatever other electricity is out there, and it shuts of if the main shuts off. Almost all rooftop systems without a battery in the US are set up the same way.

                Still, it’s important to check that things you think are disconnected do not have current flowing through them. And this makes it more important.