I’m syncoiding from my normal RAIDz2 to a backup mirror made of 2 disks. I looked at zpool iostat
and I noticed that one of the disks consistently shows less than half the write IOPS of the other:
capacity operations bandwidth
pool alloc free read write read write
------------------------------------ ----- ----- ----- ----- ----- -----
storage-volume-backup 5.03T 11.3T 0 867 0 330M
mirror-0 5.03T 11.3T 0 867 0 330M
wwn-0x5000c500e8736faf - - 0 212 0 164M
wwn-0x5000c500e8737337 - - 0 654 0 165M
This is also evident in iostat
:
f/s f_await aqu-sz %util Device
0.00 0.00 3.48 46.2% sda
0.00 0.00 8.10 99.7% sdb
The difference is also evident in the temperatures of the disks. The busier disk is 4 degrees warmer than the other. The disks are identical on paper and bought at the same time.
Is this behaviour expected?
Acronyms, initialisms, abbreviations, contractions, and other phrases which expand to something larger, that I’ve seen in this thread:
6 acronyms in this thread; the most compressed thread commented on today has 7 acronyms.
[Thread #958 for this sub, first seen 8th Sep 2024, 16:15] [FAQ] [Full list] [Contact] [Source code]